Well Pressure Tank Size Calculator

Find the minimum total pressure tank volume for your well pump from pump flow, minimum run time and pressure switch settings, using Boyle's law.

Reviewed Oct 21, 20262 cited sources (EPA, CDC, USGS, NSF and university extension)How we calculate

1 minute is a common minimum (as in Pentair's example). Check your pump or motor manufacturer's recommendation.
Commonly set 2 psi below cut-in (Nebraska DWEE worksheet).
Results update as you type.

Minimum total tank volume

34 gal

Look for a tank with at least this total volume. Its drawdown at your settings is about 10.0 gallons per pump cycle.

Drawdown needed
10 gal
Drawdown factor
29.5%

Estimate only. Not 100% accurate or guaranteed. Confirm with a water test, your utility or a qualified pro before you buy or act.

Estimate only. Check the tank manufacturer's drawdown chart and your pump's requirements, or ask a licensed well contractor.

How it works

A pressure tank stores water so the pump doesn't start and stop too often. Manufacturers size tanks from the drawdown, the water delivered between cut-out and cut-in, needed to keep the pump running a minimum time.

The drawdown factor comes from Boyle's law using absolute pressures. With the precharge equal to cut-in at 30/50 psi it works out to about 0.31, close to the 0.30 in Pentair's sizing example. A precharge 2 psi below cut-in gives slightly less drawdown.

Variable-speed (constant-pressure) pump drives use much smaller tanks. Follow the drive manufacturer's minimum tank size instead.

The formula

  • Drawdown needed = pump GPM × minimum run time (min)
  • Drawdown factor = (precharge + 14.7) × [1 ÷ (cut-in + 14.7) − 1 ÷ (cut-out + 14.7)] (absolute pressures, Boyle's law)
  • Minimum tank volume = drawdown ÷ drawdown factor

How to use this calculator

  1. Enter your pump's flow rate.
  2. Enter the manufacturer's minimum run time.
  3. Enter your pressure switch settings and tank precharge.
  4. Pick a tank whose total volume (not drawdown) is at least the result.

Frequently asked questions

Is tank size the same as drawdown?

No. A tank's drawdown is only a fraction of its total volume, for example roughly a third at 30/50 psi. Tanks are sold by total volume.

What if I live at high elevation?

Atmospheric pressure is lower at altitude, which changes the factor slightly. The calculator uses the sea-level value of 14.7 psi.

Sources

  1. Pentair WellMate pressure tank catalog: tank sizing: Drawdown = pump GPM × minimum run time; tank volume = drawdown ÷ Boyle's-law drawdown factor (30/50 psi ≈ 0.30)
  2. Nebraska Dept. of Water, Energy & Environment: Water Systems Sizing and Selection: 1 GPM per outlet, 3 GPM per outlet used at once; pressure × 2.31 ft; precharge 2 psi below cut-in